Introduction
The Veterinary Monitor has abundant monitoring functions and can be used for monitoring of cat, dog and other animals. User may select different parameter configurations according to different requirements. It adopts 100-240V~,50/60Hz for power supply, 12.1'' TFT color LCD for displaying real-time data and waveform, and up to 8-channel waveform and all monitoring parameters can be displayed simultaneously. In addition, it can be connected to the central monitoring system via wired/wireless network so as to form a network monitoring system.
This device can monitor such parameters as ECG, RESP, NIBP, SpO2 and dual- channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for moving.
Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP,CO2,IBP
1) ECG Heart rate (HR)
ECG waveform
Arrhythmia and ST-segment analysis
2) RESP Respiration rate(RR)
Respiration waveform
3) SpO2 Oxygen saturation(SpO2)
Plethysmogram(PLETH) waveform
Pulse rate(PR)
Bar graph
4) NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5) TEMP T1, T2, TD
6) CO2 (optional) EtCO2, INSCO2, AWRR
7) IBP (optional) CH1:SYS,DIA,MAP
CH2:SYS,DIA,MAP
IBP waveform
It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc
Features
1) 12.1'' TFT color LCD, multi-language interface(English,French,German,Italian,Dutch,Russian,Portuguese
,Turkish,Spanish(EU),Polish,Romania,Kazakh,Czech,Trad Chinese,Spanish(MX),Bulgarian,Chinese,
Ukraine).
2) Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
3) With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
4) Operation mode: keys and buttons.
5) Display up to 8-channel waveform on one screen.
6) Display 7-lead ECG waveform on one screen, and with ECG step function.
7) Adopt digital SpO2 technology, anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
8) NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
9) Review for 72alarm events of all parameters and 60 arrhythmia alarm events.
10) Drug concentration calculation and titration table functions.
11) Print trend table data with one-key.
12) Connect to Central Monitoring System by WiFi or wired mode.
13) AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
14) Defibrillation-proof(special leads are necessary).
Performance
1) ECG
Lead mode: 3-lead:I, II, III
5-lead:I, II, III, aVR, aVL, aVF, V
Waveform: 3-lead, 1-channel
5-lead, 2-channel
Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV
Scan speed 12.5 mm/s, 25 mm/s, 50 mm/s
HR:
Measurement and alarm range: 15~350 bpm
Resolution: 1 bpm
Accuracy: ±1 % or ±1 bpm, whichever is greater
Alarm accuracy: ± 2 bpm
ST-segment monitoring:
Measurement and alarm range: -2.0 mV~+2.0 mV
Accuracy: -0.8 mV~+0.8 mV: ±0.04 mV or ±10%, whichever is greater;
Other range: unspecified;
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R
ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Pacemaker: yes
2) RESPIRATION
Method: R-F(RA-LL) Impedance
Respiration rate:
Measurement and alarm range:0~150 rpm
Resolution: 1 rpm
Measurement accuracy: 0rpm~6rpm,No defined;7rpm~150rpm,±2 rpm or±2%
Apnea alarm: 10~40 s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
3) NIBP
Method: Oscillometry
Mode: Manual/AUTO/STAT
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
Measurement period in STAT mode:5 minutes
Measurement and alarm range: 10~270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Maximal mean error: ±5 mmHg
Maximal standard deviation: 8 mmHg
Over-pressure protection:
Other mode: 297 mmHg±3 mmHg
Dog mode: 240 mmHg±3 mmHg
Cat mode: 147 mmHg±3 mmHg
4) SpO2
Measurement and alarm range: 0~100 %
Resolution: 1 %
Measurement accuracy: 70~100 %: ±2%;
0~69 %: unspecified;
5) PR
Measurement and alarm range: 25~250 bpm
Measurement accuracy: ±2 bpm or ±2 %, whichever is greater
6) TEMP
Channel: dual-channel
Measurement and alarm range: 0~50 ℃
Resolution: 0.1 ℃
Accuracy: ±0.1 ℃
▲ EtCO2
Method: Sidestream or Mainstream
Measuring Range: 0~150 mmHg
Resolution:
0~69 mmHg: 0.1 mmHg
70~150 mmHg: 0.25 mmHg
Accuracy:
0~40 mm Hg: ±2 mm Hg
41~70 mm Hg: ±5 %
71~100 mm Hg: ±8 %
101~150 mm Hg: ±10 %
AwRR Range: 2~150 rpm
AwRR Accuracy: ±1 rpm
Apnea Alarm: Yes
▲ IBP
Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range: -50~300 mmHg
Resolution: 1 mmHg
Accuracy: ±2% or 1mmHg, whichever is greater
▲ Power supply: 100-240V~,50/60 Hz
▲ Safety classification: Class I, type CF defibrillation-proof applied part
Accessories
Digital veterinary tongue-clip SpO2 sensor (3 m)
Neonatal capsule single tube repeatable cuff (6-11cm)
NIBP extension tube
5-lead ECG lead cable (American-Standard)
ECG veterinary clip (*5)
Transvaginal TEMP probe
Power cord
User Manual
Physical characteristic
Dimension: 319 mm(L) × 167 mm(W) × 268 mm(H)