TLC6000 Dynamic 12 Channel 24 hours ECG/EKG Holter Recorder Systems Monitor Software Analyzer


Prix:
$499
Stock:
29 en stock, prêts à être livrés

Description

TLC6000 Dynamic 12 Channel 24 hours ECG/EKG Holter Recorder Systems Monitor Software Analyzer Holter ECG Monitor

 

Item Location:28197,Bremen/066004,China

To DE address, shipping from DE Warehouse 
To other countries, shipping from China 

 

Product Feature Highlights:

12-lead 

24-hour

Free PC software

one year warranty

After receiving, if there is any quality problem, we support return and exchange


Introduction
Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour (high energy battery) and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.

Function
1)Adopt 12-lead system of international standard, continuously record ECG waveform up to 24-hour.
2)Sync analysis for 12-lead, and any channels can be selected as the main analysis channel, which ensures that QRS waveform can be found accurately, and no distortion.
3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
4)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
5)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
6)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
7)With analysis functions for 5-minute, 1-hour and whole heart rate variability.
8)One-key print, convenient and fast to print the reports.
9)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
10)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
11)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.

Performance
Lead: standard 12-lead
Power supply: one “AAA” alkaline battery
Interface: USB2.0
Sampling frequency: 200Hz
Input impedance: ≥10MΩ
CMR: ≥60dB
Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%
Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.
System noise: ≤50µVp-p
Multichannel crosstalk: ≤0.2mV
Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.
Minimum measure signal: 50 µV
Timing accuracy: the overall error during 24h shall not exceed 30s.

Accessories
Lead cable (1 set)
ECG electrode (1 bag)
USB cable(1)
Software(1)
Bag(1)
User manual(1)

Physical characteristic
Recorder dimension: 81mm(L) × 60mm(W) × 22mm(H)
Weight: about 61.5g(without batteries)

Certification
CE, FDA

Customer Reviews

Based on 4 reviews
100%
(4)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
T
Thananchayan Manokaran

Yes I haven’t get yet my order..

A
Augello Giovanni

TLC6000 Dynamic 12 Channel 24 hours ECG/EKG Holter Recorder Systems Monitor Software Analyzer

D
Donato Malva
good

thanks

D
Donato Malva
good

thanks

Payment & Security

PayPal

Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.

Estimer la livraison

Customer Reviews

Based on 4 reviews
100%
(4)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
T
Thananchayan Manokaran

Yes I haven’t get yet my order..

A
Augello Giovanni

TLC6000 Dynamic 12 Channel 24 hours ECG/EKG Holter Recorder Systems Monitor Software Analyzer

D
Donato Malva
good

thanks

D
Donato Malva
good

thanks

You may also like

Recently viewed