TLC9803 Dynamic ECG Systems Digital 3-lead 24-hour Analyzer Recorder System


Prix:
$299
Stock:
Plus que 14 en stock

Description

to US address, shipping from USA Warehouse 
to other countries, shipping from China

 

Product Feature Highlights:

3-lead 

24-hour

Free PC software

one year warranty

After receiving, if there is any quality problem, we support return and exchange

 

 

Introduction

Dynamic ECG Systems adopt 3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.

Function

1)The recorder can real-time store ECG data for 24-hour.
2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
4)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
5)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
6)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
7)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
8)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
9)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
10)One-key print, convenient and fast to print the reports.
11)Perfect case management function.
12)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
13)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
14)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death

Performance

Lead: 3-lead
Record time: 24-hour
Power supply: two “AA” batteries
Interface: USB2.0
Calibration voltage: 1mV±5%
Noise level: ≤30μV
CMRR: ≥60dB
Low-frequency characteristics: time constant≥3.2s
Scan speed: 25mm/s±5%
Polarizing voltage: ±300mV, sensitivity: ≤±10%
Minimum measure signal: 50 µV p-p

Accessories

Lead cable (1 set)
ECG electrode (1 bag)
USB cable(1)
Disk(1)
Bag(1)
User manual(1)

Physical characteristic

Dimension: 111mm(L) × 60mm(W) × 25mm(H)
Weight: about 105g(without batteries)

Buy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: 
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE &TUV of Europe.

Customer Reviews

Based on 3 reviews
33%
(1)
33%
(1)
33%
(1)
0%
(0)
0%
(0)
M
Martin
Good but could be better

Yes, I can recommend this device. For Holter dynamic monitoring 3 channels are sufficient (unipolar channels). By electrode combination you can record V1, V3, V5 leads, or any other as you want. Recorded signals are good filtered, noise level is very low.
Delivered package contains bag on neck. What is missing is the chest strap for fixation to body. You can use own. But it is detail.
Another big part is supplied SW. At a glance SW looks like a little bit old-school. But all-important signal processing techniques are included. User menu is a little bit tricky for understanding but feasible to get it after some time. Overall report is full of analysis. Poincare charts are very useful. SW is stable but some views are very slow (also for just 1 hour data).

Space for improvements:
1. I feel a lack of zooming time axis!!! Only scaling in y and in 3 levels is possible. Usage of mouse wheel would be great feature.
2. Manual measurement is missing in signal view. You are not able to snap QRS vertices with appropriate precision.
3. It would be very helpful to see RR [ms] and HR [bpm] under each wave.
4. Detection of tachycardia episodes are very poor. Each tachycardia peak is marked as SV ectopy (PAC). This destroys overall arrythmia statistics.
5. Definition of ECG patterns would be also helpful because you do not know why algorithm decided to mark the complex as PAC or PVC.
6. If you are creating report and then you will update data you must click on ‘Report Update’ again and again to accept this - bug. Otherwise, only one page is printed out.
7. If you leave battery in the switched off device the battery will last only one day.
8. Signals are not possible to export in some more common data format (EDF).
In conclusion, if the CONTEC would offer more modern software with more features I would buy it. Or, AI cloud analysis would be also good business.

R
Rudolf Mengersen
Good device, but...

Small, easy to carry, one battery charge is enough for 48 hours of recording. Detailed description of the various evaluation options. Clear presentation of pathological ECG events and quantification. Overall a good long-term ECG recorder. Unfortunately, it does not have CE certification, which rules out its use in a German health insurance doctor's practice.

h
herve augier
sofware

hello
y have lost my software
can i have a new
cordialemennt

Payment & Security

PayPal

Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.

Estimer la livraison

Customer Reviews

Based on 3 reviews
33%
(1)
33%
(1)
33%
(1)
0%
(0)
0%
(0)
M
Martin
Good but could be better

Yes, I can recommend this device. For Holter dynamic monitoring 3 channels are sufficient (unipolar channels). By electrode combination you can record V1, V3, V5 leads, or any other as you want. Recorded signals are good filtered, noise level is very low.
Delivered package contains bag on neck. What is missing is the chest strap for fixation to body. You can use own. But it is detail.
Another big part is supplied SW. At a glance SW looks like a little bit old-school. But all-important signal processing techniques are included. User menu is a little bit tricky for understanding but feasible to get it after some time. Overall report is full of analysis. Poincare charts are very useful. SW is stable but some views are very slow (also for just 1 hour data).

Space for improvements:
1. I feel a lack of zooming time axis!!! Only scaling in y and in 3 levels is possible. Usage of mouse wheel would be great feature.
2. Manual measurement is missing in signal view. You are not able to snap QRS vertices with appropriate precision.
3. It would be very helpful to see RR [ms] and HR [bpm] under each wave.
4. Detection of tachycardia episodes are very poor. Each tachycardia peak is marked as SV ectopy (PAC). This destroys overall arrythmia statistics.
5. Definition of ECG patterns would be also helpful because you do not know why algorithm decided to mark the complex as PAC or PVC.
6. If you are creating report and then you will update data you must click on ‘Report Update’ again and again to accept this - bug. Otherwise, only one page is printed out.
7. If you leave battery in the switched off device the battery will last only one day.
8. Signals are not possible to export in some more common data format (EDF).
In conclusion, if the CONTEC would offer more modern software with more features I would buy it. Or, AI cloud analysis would be also good business.

R
Rudolf Mengersen
Good device, but...

Small, easy to carry, one battery charge is enough for 48 hours of recording. Detailed description of the various evaluation options. Clear presentation of pathological ECG events and quantification. Overall a good long-term ECG recorder. Unfortunately, it does not have CE certification, which rules out its use in a German health insurance doctor's practice.

h
herve augier
sofware

hello
y have lost my software
can i have a new
cordialemennt

You may also like

Recently viewed