6600B EMG is an equipment recording bioelectricity activity of nerve muscle for determining its function state, which combines with nerve conduction speed, to give patient an auxiliary diagnosis. Checking contents: EMG(electromygram), MCS(motor nerve conductor velocity), SCS(sensory nerve conductor velocity), F wave, Hreflex, RNS(repetitive nerve stimulation), Blink Reflex, VEP(visual evoked potential), BAEP(brainstem auditory evoked potential), SEP(somatosensory evoked potential), etc.
Features:
1.Professional EMG/EP operation platform and perfect test items, complete each test in the shortest time.
2.Neuro and muscle navigation system, convenient in selecting test part.
3.Powerful normal values system, contrast with normal data automatically.
4.Flexible software design, configure system parameters according to requirements.
5.High-speed data collection, electromagnetic interference suppression, Photoelectric isolation and low noise.
6.Integrative hardware system, compact in configuration and easy in moving.
Main Technical Peroformance:
-
Main system part
A/D conversion resolution 16 Bit
Sampling ratio 200kHz
Analysis time 5-5000ms
Stimulating frequency 0.1-50Hz
-
Amplifier part
Four-channel
Sensitivity 0.05μV-20mV/Grid
Earth noise EMG <= 4μV(Vpp)
EP <=0.1μV(Vpp) (1000 times in average)
Common-mode rejection ratio >= 100dB
50Hz Ban wave setting:
Upper limit for Filter-frequency 20kHz
Lower limit for Filter-frequency 1Hz
Gain amplifies 25 times-400000 times
-
Stimulator part
Constant current 0.2-100mA
Pulse width 50-1000μS
Short circuit and overloading protection
-
Auditory Stimulator
Stimulation wave 40Hz Short, Sound Stim
Stimulation polarity nondense wave, dense wave and alternant wave.
Sound strength 40-120db (5db per level)
Stimulation mode left, right, left & right
Frequency of 40Hz carrier wave 500-8000Hz
-
Visual stimulator
Mode tessellation, horizontal bar and vertical bar.
Stimulation view all-view, half-view and quarter-view
Resolution 3x4, 6x8, 12x16, 24x32, 48x64
Flash stimulator all quench,left light,right light,l&r light
Accesseries:
- Disk
- Power Cord
- Power Adapter
- USB Cable
- Audio Cable
- Earth Cable
- Current Stimulator
- One-off Bipolar Needle Electrode D039035408, 0.35*40mm, D039060706, 0.60*70mm
- Reuseable Bipolar Needle Electrode R039035408, 0.35*40mm, R039060706, 0.60*70mm
- Concentric Needle Connecting Wire
- 1mm Connecting Lead Wire
- Disc Electrode
- Ring Electrode
- Surface Electrode
- Ground Electrode(Include lead cable)
- One-off Unipolar Needle Electrode
- From 1 to 2 Conversion Cable
- Surface Electrode Conversion Cable
- Fuse 0.1A/250V, 5*20mm
- Fuse F1.6AL250V, 5*20mm
- Flash Stimulator
- Audio Stimulator